Hardware Installation
Four steps are required to installing the TCC-120/120I:
• STEP 1: Set the terminator DIP Switches
• STEP 2: Attach the Power Supply
• STEP 3: Wire the RS-422/485 Terminal Blocks
• STEP 4: Test the Connection
The details of each of these four steps are described next.
STEP 1: Set the DIP Switches
The DIP Switches on the TCC-120/120I are used to set the signal
transmission mode and to enable or disable the termination resistor.
You can configure for either 2-wire (RS-485) or 4-wire (RS-422/485)
transmission mode. Also note that your program and serial port should
be set to match the repeater’s settings.
NOTE The TCC-120/120I has two sets of DIP Switches—one set
on the top-end and the other set on the bottom-end. To
ensure proper data transmission, make sure that the two
sets of DIP switches are configured the same.
SW1— Switch 1 selects 4-wire or 2-wire mode. Set Switch 1 to the
ON position for 4-wire, and to the OFF position for 2-wire.
SW2— Switch 2 enables or disables termination. Set Switch 2 to the
ON position to enable termination, and to the OFF position to disable
termination.
Æ For easy reference, the following figures show the four possible
settings.
2-2 TCC-120/120I User’s Guide