Installation
STEP 2: Attach the Power Supply
V+
V
-
+
-
Power Supply
12 - 48 VDC
TCC-100 Series is powered by an
external 12 to 48 VDC power supply. To
connect the power supply, run two wires
from the V+ and V- terminals on TCC’s
3-connector terminal block to the DC
power supply, as shown in the figure.
Once the power supply is connected to
its power source, the PWR LED located
on TCC’s top panel should become
illuminated in red.
NOTE: TCC-100 Series provides reverse power protection. I.e., it will
automatically detect which power wire is negative, and which is positive.
STEP 3: Wire the Terminal Block
There are three wiring options available for connecting to TCC-100 Series’s
RS-422/485 terminal block.
Data +
Data
-
Tx+(B)
RTS+(B)
RTS
-
(A)
CTS+(B)
CTS
-
(A)
SGND
Tx
-
(A)
Rx+(B)(Data+)
Rx
-
(A)(Data
-
)
SGND
2-wire RS-485
When using the 2-wire RS-485 wiring option,
connect three wires from TCC-100 Series’s
terminal block to the opposite connection. As
shown in the figure, connect from Data+ to
Data+, from Data- to Data-, and from SGND
to SGND.
Tx+(B)
RTS+(B)
RTS
-(A)
CTS+(B)
CTS
-(A)
SGND
Tx
-(A)
Rx+(B)(Data+)
Rx
-(A)(Data-)
Rx+
SGND
Rx
-
Tx+
Tx
-
4-wire RS-485
When using the 4-wire RS-485 wiring option,
connect five wires from TCC-100 Series’s
terminal block to the opposite connection. As
shown in the figure, connect from Tx+(B) to
Rx+, from Tx-(A) to Rx-, from Rx+(B) to
Tx+, from Rx-(A) to Tx-, and from SGND to
SGND.
2-5