Moxa TCC-120 Betriebsanweisung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
NOTE The TCC-120/120I provides reverse power protection. It
will automatically detect which power wire is negative,
and which is positive.
STEP 3: Wire the Terminal Block
There are two wiring options available for connecting to the
TCC-120/120I’s RS-422/485 terminal block.
Data+
SGND
Data
-
R+/D+
SGND
R
-
/D
-
T+
T
-
2-wire
When using the 2-wire (for
RS-485) wiring option, you will
need to connect three wires
from each of the
TCC-120/120I’s RS-422/485
terminal blocks to the opposite
connections. Connect from
R+/D+ to Data+, from R-/D- to
Data-, and from SGND to
SGND.
Rx+
SGND
Rx
-
Tx+
Tx
-
R+/D+
SGND
R
-
/D
-
T+
T
-
4-wire
When using the 4-wire (for
RS-422 or 4-wire RS-485)
wiring option, you will need to
connect five wires from each of
the TCC-120/120I’s
RS-422/485 terminal blocks to
the opposite connections.
Connect from R+/D+ to Tx+,
from R-/D- toTx-, from T+ to
Rx+, from T- to Rx-, and from
SGND to SGND.
2-4 TCC-120/120I User’s Guide