OnCell G2100 Series User’s Manual Using Short Message Services
6-6
ATTENTION
The Target Phone Number must be specified if SMS-OUT is activated.
The Target Phone Number and Caller ID Verification must be written in international format,
starting with “+” followed by the country code.
If you leave Caller ID Verification blank, the OnCell G2100 Series modem will allow all
incoming short messages to be forwarded to the attached serial device. This includes system
broadcasts and advertisements.
Once the SMS Tunnel (SMS-OUT, SMS-IN or both) is activated and the SIM has registered to a
carrier, the GSM LED will start blinking. The mode will be Data Mode, which does not allow
users to enter AT Commands. If necessary, use the escape command (+++) from the terminal to
switch to Command Mode. Command Mode allows the use of AT commands or OnCell
Configurator.
SMS Tunnel Mode will disable auto-answering and connections by GSM, CSD, and GPRS.
The timeout between characters is 0.5 seconds. Messages that require a longer time period will be
split into 2 or more messages.
The following instructions show how to configure SMS Tunnel mode using the Wizard.
1. Connect the RS-232 port of the OnCell G2100 Series modem to a host PC. On the OnCell
G2150I, make sure the RS-232 port is connected and DIP switch 1 is set to ON.
2. Start OnCell Configurator and select the Create a new Configuration File from Wizard
option.