Click&Go User’s Manual Click&Go V2 Developing Process
3-17
Schedule Time, Range and Recurrence
Host Connection Fail
Modbus/TCP Idle Timeout.
Max value: 3,600 seconds
DI
DI refers to the status of a digital input channel. Edge detection can be used to refine the conditions.
For example, the condition DI-0=OFF is satisfied for as long as DI-0 remains off. The condition
DI-0=ON to OFF, however, is only satisfied the instant the DI-0 turns off. The transition of the
status change can also be operated using the “Change” operator so it will trigger the related action
whether it is ON-to-OFF or OFF-to-ON.
Select the IF condition to DI and click on the property (
) button to enter the DI Settings
window.