ioLogik MXIO DLL API Reference Direct I/O Command Sets
6-42
Pulse2K_SetSafeValue
This function code is used to set the safe value for a specific pulse
channel.
C/C++
Arguments
Return Value
int Pulse2K_SetSafeValue ( int hConnection,
BYTE bytChannel,
BYTE bytValue);
hConnection: The handle for an I/O connection.
bytChannel: The desired channel.
bytValue: Stores the specific pulse channel’s power on
value. The values are:
0: stop
1: start
Succeed MXIO_OK.
Fail Refer
oRe
u
nCodes.
Analog Input Commands
AI_Reads
This function code is used to read the values of contiguous analog
input channels.
C/C++
Arguments
Return Value
int AI_Reads ( int hConnection,
BYTE bytSlot,
BYTE bytStartChannel,
BYTE bytCount,
double dValue[ ]);
hConnection: The handle for an I/O connection.
bytSlot: Slot number of the I/O module, from 1 to 32.
This parameter is inactive for the ioLogik
E2000 and R2000.
bytStartChannel: Specifies the starting channel.
bytCount: The number of channels to read.
dValue: An array that stores the values of the
contiguous A/I channels; dValue[0] represents
the value of the starting channel. The unit is
Vdc for the voltage module, and mA for the
current module.
Succeed MXIO_OK.
Fail Refer to Return Codes.