ioLogik MXIO DLL API Reference Direct I/O Command Sets
6-52
AO_Write
This function code is used to write the status for a specific analog
output channel.
C/C++
Arguments
Return Value
int AO_Write ( int hConnection,
BYTE bytSlot,
BYTE bytChannel,
double dValue);
hConnection: The handle for an I/O connection.
bytSlot: Slot number of the I/O module, from 1 to 32.
This parameter is inactive for the ioLogik
E2000 and R2000.
bytChannel: The desired channel.
dValue: Stores the value of the desired channel. The
unit is VDC for the voltage channel and mA for
the current channel.
Succeed MXIO_OK.
Fail Refer
t
oRe
t
u
r
nCodes.
AO_ReadRaws
This function code is used to read the raw data values of
contiguous analog output channels.
C/C++
Arguments
Return Value
int AO_ReadRaws ( int hConnection,
BYTE bytSlot,
BYTE bytStartChannel,
BYTE bytCount,
WORD wValue[ ]);
hConnection: The handle for an I/O connection.
bytSlot: Slot number of the I/O module, from 1 to 32.
This parameter is inactive for the ioLogik
E2000 and R2000.
bytStartChannel: Specifies the starting channel.
bytCount: The number of channels to read.
wValue: An array that stores the raw data values for the
contiguous analog output channels. wValue
[0] represents the value of the starting
channel.
Succeed MXIO_OK.
Fail Refer to Return Codes.