NPort 5100 Series Web Console Configuration
5-9
Operating Settings
Click Operating Settings, located under Main Menu, to display the operating settings for both of NPort
5100s serial ports.
Real COM Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 7 min Optional
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: NPort 5100 automatically closes the TCP connection if there is no TCP activity for the given time.
After the connection is closed, the NPort 5100 starts listening for another Real COM driver connection from
another host.
Max connection
Setting Factory Default Necessity
1, 2, 3, 4 1 Required
Max connection is usually used when the user needs to receive data from different hosts simultaneously. The
factory default is 1. In this case, only one specific host can access this port of the NPort 5100, and the Real COM
driver on that host will have full control over the port.
Max. Connection 1:
Allows only 1 hosts Real COM driver to open the specific NPort 5100 serial port.
Max Connection 2 to 4:
Allows 2 to 4 hosts Real COM drivers to open the specific NPort 5100 serial port, at the same time. When
multiple hostsReal COM drivers open the serial port at the same time, the COM driver only provides a pure
Seitenansicht 31