DA-681 Series Hardware User’s Manual Hardware Installation
supply surge grounds via a removable
jumper.
8 PWR2 Surge Ground
PWR2 Surge Ground is connected to the
Chassis Ground via a jumper on the
terminal block. Surge Ground is used as the
ground conductor for all surge and transient
suppression circuitry. NOTE: Surge
Ground must be disconnected from
Chassis Ground during HIPOT (dielectric
strength) testing.
9 PWR2 Line/ DC +
PWR2 Line / DC + is connected to the
positive (+) terminal if the power source is
DC, or to the Line terminal if the power
source is AC.
10 PWR2 Neutral / DC –
PWR2 Neutral / DC – is connected to the
negative (–) terminal if the power source is
DC, or to the Neutral terminal if the power
source is AC.
For AC Power Input
1. PWR1 Line/ DC + should be connected to AC (Line).
2. PWR1 Neutral / DC should be connected to AC (Neutral).
3. Surge Ground is connected to the Chassis Ground via a braided cable or other appropriate
grounding wire. Surge Ground is used as the ground conductor for all surge and transient
suppression circuitry internal to the PT-7324 unit.
4. Chassis Ground should be connected to the AC Ground terminal.
ATTENTION
1. Equipment must be installed according to the applicable country wiring codes.
2. Surge Ground MUST be disconnected from the Chassis Ground during HIPOT (dielectric
strength) testing.
3. All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where
users require the inputs to be isolated from the ground, remove the ground braid between
Surge and Chassis Ground. Note that all line-to-ground transient protection circuitry will be
disabled.